To display the content appropriate for your location, we have set the country to: , language: EN. You can continue with these settings or change them.
Change Continue

JAG F

JAG F plate and frame heat exchangers are a new, revolutionary solution, ensuring not only increased flow turbulence, but also extensive heat exchange surface.

JAG F

JAG F plate and frame heat exchangers are a new, revolutionary solution, ensuring not only increased flow turbulence, but also extensive heat exchange surface.

Innovative JAG heating plate corrugations pattern, the result of 6 years of work on product development, allows for more compact, lighter, and above all more efficient exchanger, perfectly adjusting to individual requirements. The new “jagged” channel design increases flow turbulence, which improves heat exchange and also decreases sediment accumulation.

The additional benefit is an extensive heat exchange surface and decreased overall pressure drops. JAG F plate heat exchanger also features a range of technical solutions for the frame construction that make the highly efficient JAG F plate heat exchanger a reliable solution in many applications.

Features

  • High thermal performance thanks to innovative heating plate corrugations pattern
  • Technical solutions facilitating the exchanger installation and operation
  • Option to adjust the exchanger design to the required installation operating parameters by selecting proper number and size of the heating plates
  • Heating plates made of stainless steel or titanium to be used in aggressive media systems or pools with salt water
  • Dismountable design – allows for cleaning and extension, if necessary
  • Wide range of products
  • Made of stainless steel (optional)

Design

  • Metal roller
    Metal roller
    in larger models – allows for easy sliding of rear plate, decreasing time and effort of maintenance. The rollers are equipped with Teflon or polyamide slides that stabilize the rear plate
    Metal roller
  • U-leg
    U-leg
    Facilitates plate pack installation. It is also intended for mounting the heat exchanger to the mounting platform
    U-leg
  • Additional front feet
    Additional front feet
    stabilize heat exchanger and facilitate its firm mounting to the mounting platform
    Additional front feet
  • Special carrying bar profile
    Special carrying bar profile
    Intended for suspending heater plates in larger models.It is also intended for proper plates positioning. It is part of the five point mounting system
    Special carrying bar profile
  • Lock washer
    Lock washer
    facilitates and speeds up unscrewing of the tightening bolts
    Lock washer
  • Front and rear cover plate
    made of painted carbon steel, different colors available on demand
  • Connections size: DN32 to DN350
JAG F
Design

Finite element method

The application of the Finite Element Method (FEM Analysis) was intended to optimize the design in terms of durability, mainly by improving the stress distribution on cover plates and modifying fasteners, which led to expanding the scope of working parameters of the device.

Finite element method

JAG PLATE – reinvented

  • Innovative JAG corrugations pattern
    Innovative JAG corrugations pattern
    Innovative JAG corrugations pattern
  • Triple heater plates positioning system
    Triple heater plates positioning system
    Triple heater plates positioning system
  • Modified distribution area
    Modified distribution area
    Modified distribution area
  • Optimized sealing surface
    Optimized sealing surface
    Optimized sealing surface
  • Additional plate reinforcement
    Additional plate reinforcement
    Additional plate reinforcement
  • Patented hybrid gasket mounting system
    Patented hybrid gasket mounting system
    the new patented gasket features two mounting methods and optimized, unique shape
    Patented hybrid gasket mounting system
  • Five point mounting system
    Five point mounting system
    Five point mounting system
  • 32–250 mm ports
JAG plate
JAG PLATE – reinvented

Gasket design

  • Lock-in method
    Lock-in method
    - specially designed bolts are pressed into the corresponding cut-outs in the heating plate. The lock-in locks stabilize the gasket on the plate during installation
    Lock-in method
  • Lock-on method
    Lock-on method
    - a T-shaped attachment grips the proper fragment of the profiled edge of the heating plate, mounting the gasket to the vertical side of the plate. This facilitates and speeds up the installation process
    Lock-on method
  • Optimized, unique shape of the gasket
    Optimized, unique shape of the gasket
    ensures perfect sealing, even in high pressure applications
    Optimized, unique shape of the gasket
  • Highest production standards
    high quality materials and reliable deliveries
JAG Gasket
Gasket design

Applications

Select the type of contact

Cairo Softwere

Easy selection of the heat exchanger thanks to the Cairo Selection Software

Go to CAIRO
Go to Contact

Do you have questions concerning our products?

Go to Contact

Newsletter

Product and technological news
Send
Dziękujemy! Skontaktujemy się niebawem!